0
Direct heat/circulating high temperature heat pump water heater, outlet temperature 95°C, COP≥2.6,
can be customized anti-corrosion direct heat hot water heater, secondary heat exchanger is made of FEP material, outlet water temperature can reach 85°C, suitable for semiconductor, hardware, electroplating, chemical and other industries
| Product model |
NCSN-170IIMB(4)D |
| Power supply | 380V 3N~ 50Hz |
| Electric shock protection rating | Class I |
| Protection level | IPX4 |
| Heat pump rating custom heat | 170kW |
| Heat pump rated power consumption | 75kW |
| The maximum power consumption of the heat pump | 105kW |
| Maximum working current of the heat pump | 200A |
| maximum pressure | 4.0Mpa |
| Refrigerant | R410a、R134a/10kg, 30kg |
| Noise | ≤75 dB(A) |
| Dimensions (L*W*H) | 1200*2535*2960 |
| Net weight | 2500 kg |
The model, parameters, and performance will be changed due to product improvements, and the specific parameters are subject to the product nameplate.