Drying method:
In the open-loop drying mode: the unit heats the drying room, and the external moisture exhaust fan is used to dry the material while recovering the waste heat from the exhaust, which can be recycled to the fresh air, outdoor heat absorption evaporator, etc.
In closed-loop drying mode: the unit dehumidifies the drying room internally, and uses the latent heat of moisture condensation to heat the air in the drying room. When the unit dehumidification is not enough, the dehumidifying fan can also be used to exhaust moisture at the same time.
Application areas:
Mosaic, fruit, rhizome, tobacco, meat, aquatic, industrial.
Conventional models:
7P、15P、25P
Product advantages:
1. Open/closed loop switching, flexible and changeable;
2. Reduce the influence of environmental temperature and humidity;
3. Integrate drying and dehumidification;
4. It can heat up and dehumidify, heat up and dehumidify;
5. It can realize 100% collection of pure dew and extract the essence of pure dew.
Product name |
|
Air source heat pump dryer |
|
Type |
/ |
|
|
Product number |
/ |
NCYNKB-22IIDXH/01 |
NCYNKB-43IIDXH/01 |
Power supply form |
V / Ph / Hz |
380/3/50 |
380/3/50 |
Protection level |
/ |
PX4 |
IPX4 |
Type of protection against electric shock |
/ |
Class I |
Class I |
Heat pump rated heating capacity |
kW |
twenty three |
45 |
Heat pump rated power consumption |
kW |
6 |
12 |
Rated working current of heat pump |
A |
11.5 |
twenty three |
Rated power consumption of electric heating |
kW |
12 |
12 |
Rated working current of electric heating |
A |
twenty two |
twenty two |
Maximum power consumption |
kW |
20 |
30 |
Maximum working current |
A |
39 |
53 |
Dehumidification capacity (5C°C/50%RH) |
kg/h |
15 |
30 |
Dehumidification capacity (50°C/80%RH) |
kg/h |
26 |
52 |
Drying temperature |
°C |
20~75 |
20~75 |
Maximum working pressure of high/low pressure side |
MPa |
3.0/0.75 |
3.0/0. 75 |
Maximum working pressure on discharge/suction side |
MPa |
3. 0/0.75 |
3.0/0. 75 |
Maximum pressure of evaporator |
MPa |
4 |
4 |
Refrigerant charge |
kg |
R134a/4. 5 |
R134a/2X4.5 |
Noise |
dB (A) |
≤70 |
≤70 |
Dimensions |
mm |
1750X1200X1700 |
2260X1550X1825 |
Net weight |
kg |
450 |
750 |
Models, parameters, and performance will be changed due to product improvements. The specific parameters are subject to the product nameplate.