  • Drying method:
    The unit carries out internal circulation dehumidification in the drying room, and uses the latent heat of water condensation to heat the air in the drying room.

     

    Application fields:
    food, flowers, traditional Chinese medicine decoction pieces, aquatic products, industrial and other industries.

     

    Conventional models:
    7 P, 15P, 25P

     

    Product advantages:
    1. Easy installation;
    2. Closed drying; Clean and hygienic, zero pollution, zero emission;
    3. It is not affected by region, season, environmental temperature and humidity; All-weather drying, stable energy efficiency;
    4. It can recover the moisture of materials with high nutritional value.

  • Product name

     

    Air source heat pump dryer

    type

    /

    Closed dehumidification all-in-one machine

    Product model

    /

    NCYNB-23IIDXH/01

    NCYNB-23IIDXS/01

    Power form

    V/Ph/Hz

    380/3/50

    380/3/50

    Ingress protection

    /

    IPX4

    IPX4

    Type of protection against electric shock

    /

    Category I

    Category I

    Dehumidification capacity (50°C/80%)

    kg/h

    26

    26

    Dehumidification capacity (50°C/50%)

    kg/h

    15

    15

    Rated operating power of the heat pump

    kW

    6.2

    6.2

    Rated operating current of the heat pump

    A

    11

    11

    Electric heating power

    kW

    6

    6

    Maximum operating power of the heat pump

    kW

    15

    15

    Maximum operating current of the heat pump

    A

    25

    25

    Drying temperature

    °C

    20~75

    20~75

    Maximum working pressure on the high/low-pressure side

    MPa

    3.0/0.75

    3.0/0.75

    Maximum working pressure on the drain/suction side

    MPa

    3.0/0.75

    3.0/0.75

    The maximum pressure of the evaporator

    MPa

    4

    4

    Refrigerant charge

    kg

    R134a/3. 0

    R134a/3. 0

    noises

    dB (A)

    ≤65

    ≤65

    Dimensions

    mm

    1485X905X1635

    1300X905X1700

    net weight

    kg

    300

    300

       

    7HP closed rear air outlet

    7HP closed upper air outlet

    The model, parameters and performance will be changed due to the improvement of the product, and the specific parameters are subject to the product nameplate.