Language

0575-89303990

Closed integrated machine

15P Closed integrated machine

0
Views: 13
Contact us PDF download
  • Drying method:
    The unit carries out internal circulation dehumidification in the drying room, and uses the latent heat of water condensation to heat the air in the drying room.

     

    Application fields:
    food, flowers, traditional Chinese medicine decoction pieces, aquatic products, industrial and other industries.

     

    Conventional models:
    7 P, 15P, 25P

     

    Product advantages:
    1. Easy installation;
    2. Closed drying; Clean and hygienic, zero pollution, zero emission;
    3. It is not affected by region, season, environmental temperature and humidity; All-weather drying, stable energy efficiency;
    4. It can recover the moisture of materials with high nutritional value.

  • Product name

     

    Air source heat pump dryer

    type

    /

    Closed dehumidification all-in-one machine

    Product model

    /

    NCYNB-45IIDXS/01

    NCYNB-45IIDXS/01

    Power form

    V/Ph/Hz

    380/3/50

    380/3/50

    Ingress protection

    /

    IPX4

    IPX4

    Type of protection against electric shock

    /

    Category I

    Category I

    Dehumidification capacity (50°C/80%)

    kg/h

    52

    52

    Dehumidification capacity (50°C/50%)

    kg/h

    30

    30

    Rated operating power of the heat pump

    kW

    12.5

    12.5

    Rated operating current of the heat pump

    A

    22

    22

    Electric heating power

    kW

    12

    12

    Maximum operating power of the heat pump

    kW

    30

    30

    Maximum operating current of the heat pump

    A

    50

    50

    Drying temperature

    °C

    20~75

    20~75

    Maximum working pressure on the high/low pressure side

    MPa

    3.0/0.75

    3.0/0.75

    Maximum working pressure on the drain/suction side

    MPa

    3.0/0.75

    3.0/0.75

    The maximum pressure of the evaporator

    MPa

    4

    4

    Refrigerant charge

    kg

    R134a/2X3.0

    R134a/2X3.0

    noises

    dB (A)

    ≤70

    ≤70

    Dimensions

    mm

    1610X1510X1885

    1610X1510X1885

    net weight

    kg

    650

     
       

    15HP closed rear air outlet

    15HP closed upper air outlet

    The model, parameters and performance will be changed due to the improvement of the product, and the specific parameters are subject to the product nameplate.